200 MHz, Dual Channel, Delayed Sweep
Built-in 6 Digit Universal Counter
Auto Set
TV-Line Selection (NTSC, PAL, SECAM)
10 Sets Memory for SAVE & RECALL of Front Panel Setting
Cursor Readout with 7 Measurements
Panel Setup Lock of Digital-Control Functions
Buzzer Alarm
LED Indicators
Trigger Signal Output
Z-Axis Modulation Input
SMD Technology, High Stability and Reliability
SPECIFICATIONS
CRT
Type 6-inch rectangular type with internal graticule;
0%, 10%, 90% and 100% markers. 8 x 10 DIV (1 DIV=1 cm)
Phosphor P31
Accelerating Potential 14 kV approx.
Illumination Continuously adjustable
Z-axis input Coupling : DC
Sensitivity : 5V or more
Maximum input voltage : 30V (DC+AC peak) at 1kHz or less
Bandwidth : DC ~ 5MHz
--------------------------------------------------------------------------------
VERTICAL SYSTEM
Sensitivity 2mV ~ 5V/DIV,11 step in 1-2-5 sequence
Sensitivity Accuracy < 3% (5 DIV at the center of display)
Vernier Vertical Sensitivity Continuously variable to 1/2.5 or less panel-indicate value
Bandwidth(-3dB) DC ~ 200MHz (2mV/DIV : DC ~ 20MHz)
Rise Time 1.75nS (2mV/DIV : 17.5 nS)
Signal Delay Leading edge can be monitored
Max. Input Voltage 400V (DC+AC peak) at 1kHz or less
Input Coupling AC, DC, GND
Input Impedance 1M?+2%// approx. 25pF
Vertical Mode CH1, CH2, DUAL (CHOP/ALT), ADD, CH2 INV.
Bandwidth Limited 20MHz
Common-Mode Rejection Ratio 50 :1 or better at 50kHz
Dynamic Range 8 div at 100MHz; 5 div at 200MHz
--------------------------------------------------------------------------------
HORIZONTAL SYSTEM
Horizontal Modes MAIN(A), ALT, DELAY(B)
A(main)Sweep Time 20nS ~ 0.5S / DIV, continuously variable (UNCAL)
B(delay)Sweep Time 20nS ~ 50mS/DIV
Accuracy + 3% (+ 5% at x 10 MAG)
Sweep Magnification x 10 (maximum sweep time 2nS / DIV)
Hold Off Time Variable
Delay Time 1µS ~ 5S
Delay Jitter Better than 1:20000
Alternate Separation Variable
--------------------------------------------------------------------------------
TRIGGER
Trigger Modes AUTO, NORM, TV
Trigger Source CH1, CH2, LINE, EXT, EXT/10
Trigger Coupling AC, DC, HFR, LFR, NR
Trigger Slope "+" or "-" polarity or TV sync polarity
Trigger Sensitivity
Trigger Level Range INT :±4DIV or more; EXT :±0.4V or more; EXT/10 :±4V or more
TV Triggering Mode : TV-V, TV-H, TV-LINE
TV-Line Selection
Max. External Input Voltage 400V (DC+AC peak) at 1kHz
External Input Impedance 1MΩ+ 5%, // approx. 25pF
--------------------------------------------------------------------------------
X-Y OPERATION
Mode X-axis : selectable CH1, EXT, EXT/10
Y-axis : selectable CH1, CH2, CH1 and CH2
Sensitivity Accuracy 2mV ~ 5V / DIV ±3%; EXT : 0.1V / DIV±5%; EXT / 10 :1V / DIV±5%
X-axis Bandwidth DC ~ 500kHz (-3dB)
Phase Error 3º or less from DC ~ 50kHz
--------------------------------------------------------------------------------
OUTPUT SIGNAL
Trigger Signal Output Voltage : approx. 25mV/DIV into 50Ω
Frequency response : DC ~ 10MHz
Calibrator Output 1kHz Squarewave, 2Vpp±2%
--------------------------------------------------------------------------------
CURSOR READOUT FUNCTION
Cursor Measurement Function △V,△V%,△VdB,△T,1/△T,△T%,△θ
Cursor Resolution 1 / 100 DIV
Effective Cursor Range Vertical : ±3DIV ; Horizontal : ±4DIV
Panel Setting Display Vertical : V/DIV(CH1,CH2), UNCAL, ALT/CHOP/ADD, INV, probe factor, AC/DC/GND
Horizontal : S/DIV(MTB,DTB), UNCAL, x 10MAG, delay time, HO
Trigger : source, coupling, slope, level, TV-V, TV-H
Others : X-Y, lock, save/recall MEM 0-9
--------------------------------------------------------------------------------
AUTO MEASUREMENT FUNCTION
Parameter Function FREQ, PERIOD, ±WIDTH, ±DUTY ( + or - polarity selected by trigger slope)
Display Digits Max. 6-digits, decimal
Frequency Range 50Hz ~ 200MHz
Accuracy 1kHz ~ 200MHz : +0.01%; 50Hz ~ 1kHz : +0.05%
Measuring Sensitivity >2 div (Measuring source selected from CH1 and CH2 as synchronous signal sources)
--------------------------------------------------------------------------------
SPECIAL FUNCTION
Auto Set Input Channel : CH1, CH2; Frequency Response 50Hz~50MHz
Panel Setting Save & Recall 10 sets
Panel Setups Lock Provided
--------------------------------------------------------------------------------
POWER SOURCE
AC 100V / 120V / 230V + 10%, 50 / 60Hz
--------------------------------------------------------------------------------
ACCESSORIES
Power cord x 1; Instruction manual x 1; Probes(10:1/1:1) x 2
--------------------------------------------------------------------------------
DIMENSIONS & WEIGHT
310(W) x 150(H) x 470(D) mm; Approx. 9k