Parameters | Specifications |
Output voltage | 200 to 4500V ± 10%, 10V step |
pulse parameters at 50 ohm | Pulse rise time 5ns ±30% pulse width 50ns ±30% |
pulse parameters at 1k ohm | Pulse rise time 5ns ±30% Pulse width 35 ns to 150 ns |
Polarity | Positive, negative, polarity change burst by burst |
Pulse frequency | 0.11kHz to 1000kHz ±5% (0.11kHz to 1kHz at 0.01 kHz step 1kHz to 10kHz at 0.1kHz step 10kHz to 100kHz at 1kHz step 100kHz to 1000kHz at 10kHz step) |
Burst duration | Number of pulses within a burst: 1 to 1000 or continuous (limited by settings for pulse frequency and burst period) Settings by number of pulses and duration are available |
Burst period | 10 to 1000 ms ±10%, 10ms step (alternative mode: >510 ms) |
"Continuous" mode operation | 50 KHz max, limited by output voltages |
Dynamic output Z | 50 ohms ±20% |
Output connector | coaxial (PULSE OUT), outlet panel |
Coupling capacitor | 33nF |
DC blocking capacitor | 10nF ±20% |
Frequency modulation | deviation: -10% to setting. |
Timer (test duration) | 1s to 99h 59m 59s 10 minutes max in the "continuous" and alternate polarity modes |
External trigger | TTL down edge Minimum trigger interval acceptable: 10ms |
Burst timing | non-synch. | Irrespective of EUT mains frequency |
synch. | Synchronizes with the EUT mains frequency 0 to 359 degrees ±2 degrees, 1 degree step Burst period: 50/60Hz |
Internal CDN | 85 to 500V AC 50A 50/60Hz 5-wire three-phase, 125V DC 50A |
Coupling line | L1, L2, L3, N, PE |
Coupling mode | Line (s) to ground mode only |
Outlet | Plug receptacle placed on the front panel |
EUT mains switch | Turn on/off controllable by front panel |
Emergency switch | Turn off pulse generation and interrupt the EUT mains. |
Printer interface | Centronics (ESC/P) |
Included accessories | Line input cable/ Mains cable Accessory bag / Instruction manual Outlet panel: 500V AC 50A, 3-pin |
Optional accessories | GP-IB/RS-232C interface Coupling clamp CDN unit Outlet panel (various types outlets) Attenuator (50 ohm coaxial attenuator) Infra-red remote controller Memory card Warning lamp Printer cable |
Ambient (operation) | 10 to 40 degrees, 25 to 75% relative humidity |
Dimensions and (projection included) | (W) 332 x (D)443 x (H)420 mm |
Weight | 20 kgs. |
Power supply | 90V to 264V AC, 50/60 Hz |