SPECIFICATIONS |
Test Current |
AC 3A ~ 32A |
|
Test Voltage |
MAX 8V AC Typically |
|
Measuring Resistance Range |
0 to 0.12Ω, 0 to 0.6Ω 2 ranges |
|
Measuring Accuracy |
3A ~ 5A, +10% of full scale |
5A ~ 32A, +5% of full scale |
|
Current Meter |
Indicate the testing Current and Setting value of Warning |
|
Resistance Meter |
Indicate the testing Resistance and Setting value of Fail and SUBTRACTION |
|
Switching |
Zero-start operating switch |
|
Timer |
1S, 10S, 1MIN, 10MIN 4 ranges |
|
Warning |
Monitor the variation test current, when the test current is beyond+10% of the setting value, the warning operation will proceed. |
The setting value from 3A ~ 32A |
|
Subtraction |
The resistance of testing line can be subtracted from the test value |
The subtraction range from 0 ~ 0.1Ω |
Accuracy is ±10% |
|
GO-NOGO Set |
If the test reading value is beyond the setting value, the fail will be acting, otherwise the pass will proceed. |
The setting value from 5% ~ 100% of the test range |
Accuracy is ±15% of full scale (3A ~ 5A);±10% of full scale (5A ~ 32A) |
|
Remote Control |
Input high voltage range from 11V ~ 15V, low voltage range from 0 ~ 4V and input low current range below 20mA |
|
Test Mode |
Normal:if the warning acted then the test will stop |
Continue:if the warning acted then the test will be continuously |
|
Buzzer |
A Buzzer is sounded when the test fail acted |
|
Test Frequency |
50Hz or 60Hz independent by Line Voltage |
|
Output Signal |
TEST, GO, NG, WARNING, READY, MONITOR |
|
Power Source |
AC 100V/120V/220V/240V±10%, 50/60Hz |
|
Accessories |
Test Lead GHT-115 x 1, Instruction manual x 1, Power cord x 1 |
|
Dimensions & Weight |
430(W) x 178(H) x 510(D) mm, Approx. 21kg |
|