FEATURES
- Lightning Surge Simulator conforming to IEC61000-4-5 ed2 Standard
- Ring wave conforming to ANSI/IEEE C62.45 available
- Max. voltage 6.6kV output focusing on the practical use
- Monitor terminal standard equipped so as for easy waveform pre-checking
- Interlock built-in as the emergency stop function for safety
- Remote control software from PC ready as the option besides the stand-alone operation
- AC/DC CDN standard equipped. Available up to 3-phase AC500V 50A as the option
- CDN for Telecom lines, CDN for interconnection lines, isolation transformer, etc. ready as the option
SPECIFICATIONS <Common>
Parameter |
Specifications |
Polarity |
Positive / Negative |
Interval |
(Minimum charging time) to 999 sec. 1 sec. step |
No. of output setting |
1 to 999 times 1 time step |
<Surge generating unit>
Parameter Specifications
1.2/50μs-8/20μs
Combination waveforms |
Voltage surge |
Output voltage 0.5 to 6.0kV ±10% |
Front time 1.2μs±30% |
Duration 50μs±20% |
Current surge |
Output current 250 to 3000A ±10% |
Front time 8μs±20% |
Duration 20μs±20% |
Minimum charge time |
10 Sec. |
Output impedance |
2Ω±10% |
0.5μs-100kHz Ring wave |
Voltage surge |
Output voltage 0.5 to 6.0kV ±10% |
Rise time 0.5μs±0.15μs |
Frequency: 100kHz ±20kHz |
Current surge |
2nd peak voltage 40-110% of 1st peak voltage |
3rd peak voltage 40-80% of 2nd peak voltage |
4th peak voltage 40-80% of 3rd peak voltage |
Minimum charge time |
5 Sec. |
Output impedance |
12 Ω±3 6 Ω at 12 Ω selection in interruptive resistance
30 Ω±8 Ω at 30 Ω selection in interruptive resistance |
Coupling network |
Line - Line : 18μF, Line - PE : 10Ω+9μF,
Line - PE simultaneous coupling (L+N-PE) : 9μF/9μF |
Decoupling coil |
1.5mH |
AC EUT power capacity |
Single phase AC 240V 16A MAX (50/60Hz) |
DC Eat power capacity |
DC125V/16A MAX |
Phase angle control |
0 to 360°±10°, Based on set injection / return angle |
<Surge Generating Unit for External CDN>
Parameter Specifications
10/700μs-5/320μs Combination waveforms |
Voltage surge |
Output voltage 0.5 to 6.0kV ±10% |
Front time 10μs±30% |
Duration 700μs±20% |
Current surge |
Output current 12.5 to 150A ±10% |
Front time 5μs±20% |
Duration 320μs±20% |
Minimum charge time |
15 Sec. |
Output impedance |
40Ω±10% |
<Others>
Parameter |
Specifications |
Voltage monitor |
BNC output, 1/1000±10% |
Current monitor |
BNC output, 1mV/A±10% |
External communication |
RS-232C optical communication |
Power supply |
AC100V to 120V±10%, AC200V to 240V±10%,50/60Hz, Power consumption: Less than 300VA |
Dimensions |
W430×H515×D500 mm (Projection excluded) |
Mass |
Approx. 65kg |