Parameters |
Specifications |
Remarks |
Compliant standard |
IEC 61000-4-11 |
|
Number of lines |
Single phase |
|
Test mode |
Interruption AC/DC |
Synchronous |
PC/local |
Short circuit |
|
Asynchronous |
PC |
Synchronous/Asyn chronous |
PC |
Open circuit |
Dip and swell |
Synchronous |
PC/local |
Asynchronous |
PC |
Variation |
Asynchronous |
PC/Local Only 2s-1s-2s standard defined test available in local mode |
Input voltage range |
AC90~264V, 50/60 Hz DC0~125V |
|
Output voltage range |
AC0V~120% of input voltage DC0V~input voltage |
AC290V max |
Output VA |
4.224kVA |
Continuous |
Output current capability |
AC |
100% of input voltage |
16A rms |
Continuous |
70% of input voltage |
23A rms |
<5S |
40% of input voltage |
40A rms |
<5S |
DC |
16A |
Continuous |
Peak inrush current drive capability |
AC100~120V |
>250A |
at 100% output, <10ms |
AC220~240V |
< 500A |
Load regulation |
100% of input voltage 0~16A rms |
<5% |
|
70% of input voltage 0~23A rms |
<7% |
100% of input voltage 0~40A rms |
<10% |
Overshoot/undershoot |
<5% |
100 ohm loaded |
Rise time/fall time |
1~5㎲ |
100 ohm loaded |
Normal voltage setting |
Setting by percent |
PC |
~120% |
10V minimum |
Local |
100% |
|
Setting by voltage |
PC |
10V~290V |
5V step |
Accuraey |
±5V |
0V~16A output |
Dip/Swell level |
Setting by percent |
PC |
Short/Open selectable for 0% (interruption) |
0~120% |
|
Local |
Short circuit for 0% (interruption) setting |
0/40/70/120% |
4 steps |
Setting by voltage |
PC |
Short/Open selectable for 0V (interruption) |
0~290V(0~120%) |
5V step |
Accuraey |
±5V |
Repetition of events |
No. of events |
PC |
1~1000 or continuous |
1 event step |
Local |
1, 3, 5, 10, 30, 50, 100 or continuous |
8 steps |
Interval cycle |
Setting by cycle |
Synchronous |
PC |
0.5~5000.5 cycles |
0.5 cycle step |
Local |
1,3,5,10,30,50,100,300,500 cycles, 10s |
10 steps |
Setting for short duration |
Synchronous |
PC |
1~100s |
1s step |
Asynchronous |
10ms~100s (50Hz) 8.3ms~100s (60Hz) |
0.1 ms step |
Setting by time |
Setting for long duration |
Asynchronous |
1s~10h |
1s step |
Dip cycle |
Setting by cycle |
Synchronous |
PC |
0.01~5000 cycles |
0.01 cycle step |
Local |
0.5, 1, 5, 10, 25, 50 cycles |
6 steps |
Setting by time |
Setting for short duration |
Synchronous |
PC |
0.1 ms~100s |
0.1ms step |
Asynchronous |
0.1 ms~100s |
0.1ms step |
Setting for long duration |
Asynchronous |
1s~10h |
1s step |
Dip phase (Starting phase angle of events) |
Setting by phase angle |
Synchronous |
PC |
0˚~359˚ |
1 step |
Local |
0, 45, 90, 135, 180, 225, 270, 315 |
8 steps (45 degrees step) |
Setting by time |
PC |
0~19.9 ms for 50Hz |
0.1ms step |
0~19.9 ms for 60Hz |
Voltage variation test |
Setting by time |
Changing time |
Asynchronous |
PC |
0.1s~10 s at least 0.1s required for 10% change of input |
0.1s step |
Changed time |
0~10s |
Interval |
0~100s |
0.1s step |
Test level |
PC |
0~120% |
0.1s step |
Memory |
Local |
5 tests |
Test sequence stored up to 10 steps when controlled by PC |
PC |
10 steps |
Equipment input |
AC100~115V/200~240V 10%, 50/60Hz, 120VA |
External interface |
optical RS-232 |
Operating temperature |
15~35 ℃ |
Operating humidity |
25~75%R.H. (No dewing) |
Dimensions |
(W)430 (H)745 (D)600mm(projection excluded) |
Weight |
Approx.150 kgs. |